Chemiluminescence Microplate Photoncounter
MTP-700CL / MTP-700Lab
Hardware | Specifications
Photoncounting Photomultiplier offers highly- sensitive luminescence detection and dual wavelength measurement.
Application
Optional Interference filters enable to detect two luminescence separately in addition to detection of whole luminescence intensity without interference filter.
  • Bioluminescence Method
    Luciferase / Dual Luciferase
    ATP, Luciferin
  • Chemiluminescence Method
    Dioxetane compound, (Iso)Luminol, Acridinium ester
    Luminometry of β-galactosidase, Alkaline phosphatase
  • Instantaneous Luminescence Detection
    Built-in assures detection of momentary luminescence
  • Photoncounting Photomultiplier
    Dedicated detector realizes highly sensitive detection.
    Optional Interference filters enable to detect single and dual luminescence separately in addition to detection of whole luminescence intensity without interference filter.
  • Various Measuring Parameters
    Gating time: From 0.1 to 999.9 seconds
    Repeating time of Reading: From 1 to 999 times
    Interval time between repeated readings: From 0.1 to 999.9 seconds
  • Built-in Dispenser System
    Independent Dual Channel
          Dispensing Volume: 50 to 200µL
  • Mixing Function:
    Shaking Way: Round/Linear
    Mixing Intensity: 3-step
    Mixing Time: Selectable in 1 second increments between 5.0 to 99.9 seconds
  • Temperature Control
    Temperature Setting: Selectable from 7ºC above/35ºC to 45ºC in 1ºC increments (Accuracy: ±0.5ºC)


    KF-700 Data Treatment Software
  • Hardware Requirement
    OS : Windows98, Me, 2000, XP
    Memory : Recommended memory quantity of each OS
    Hard Drive Space : 5MB or more
    Connection to Reader : RS-232C port
  • Working Curve Calculation
    Scale of Graph (X,Y) : Linear or Log
    Blank setting : At max. 8 points
    Standard Concentration : Up to 12 concentration with 6 replicates at max
    Regression Formula : Linear through OP and quadratic function
    Logit-Log : Linear, Quadratic, Cubic
    Logistic : 4 and 5-coefficient
    Spline : Linear and Cubic
    NSB : B / Bo calculation for competitive ELISA
          Positive / Negative judgment
  • Cut off Calculation
    Selectable Calculation Routines, Cut off judgment
  • Data Analysis
    Data Conversion : Factor multiplication, Single Standard working Curve
    Data Treatment : ±judgment, Data aliquot level judgment, Row-by-row/Line-by-line subtraction
  • Accuracy check-up
    Average, CV% SD of Resulting Data (Row-by-row, Line-by-line and Whole plate)
  • Time Course Software
    Area : Area of specified section
    Average Slope : Average slope between specified starting section and least upper bound of OD
    : Average slope between greatest lower bound and least upper bound
    Maximum gradient : Maximum slope in specified section
    Time : The time needed to achieve the specified measured data after start of measurement
  • PC Control (Enables Reader Control, Protocol Setting and Data analysis.)
    PC Control function enables reader control on PC.
          • Single/Dual wavelength reading, Regional Reading
          • Selection of endpoint or time course measurement
          • Control of dispensing system
          • Setting of mixing function
          • Sensitivity tuning
  • Select Indicator
    LED indicators display selected setting items making sophisticated condition setting easy to make .